Application of cables and cords in power installations. German din vde standards standard din vde 0100 din vde 0100 part 100 din vde 0100 part 410 din vde 0100 part 430 din vde 0100 part 482 din vde 0100 part 520 din vde 0100 part 530 din vde 0100 part 559 din vde 0100 part 701 to part 705 din vde 0100 part 720 din vde 0100 part 726. Current carrying capacity and indications for calculation. Three main cores and the protective conductor symmetrically split in the interstices. Nominal voltage 300500 v following din vde 02983 testing voltage 2000 v following din en 50395 3 9 052019 guarantee. Umrechnungsfaktoren nach din vde 02984, tabelle 21. If you find this website valuable and appreciate it is open and free for everybody please contribute by. Currentcarrying capacity for undisturbed service din vde 0298 t4 pos. For free hanging operation the cables are twistable. Within cables, this includes power, fibre optic for communication and fire performance cables including those with halogen free properties for applications requiring additional protection for essential equipment and human life in the event of fire. The connecting cables supplied are sufficiently dimensioned for the rated currents specified. Recommended currentcarrying capacity for sheathed and nonsheathed cables for fixed wirings in buildings and for flexible cables and cords. The former occurs frequently when a number of collectors are present per system.
Conductor structure according to din vde 0295 iec 60228 cross multistrand manystranded finely stranded superfine strand section conductor conductor conductor conductor mm2 class 2 class 5 class 6 vde 0295 vde 0295 vde 0295 number of strands and individual strand mm 0. Conductor copper, finely stranded f, class 5 in accordance with din en 60228 iec 60228 insulation vulcanized rubber compound, basis epr, compound ei4 in accordance with en 503631 color code colored in accordance with din en 505251. Minimum bending radii according to din vde 0298 part 3 reeling operation no restriction. Conductor structure according to din vde 0295iec 60228. Erection of power installations with rated voltages below. Halogen free cables with improved characteristics in the case of fire, with reduced fire propagation and continuance of isolation for use in the containment of nuclear power plants. Global data brand protomont type designation nsshoeu standard din vde 0250812 certifications approvals ma china msha p1893 fire certificate of russian federation trcertificate gost k gost b notes on installation notes on installation maximum submersing depth 2000 meters design features. For noncompliance of the values a short longevity is to be expected. Section analysis vde download for electrical engineers. For reasons, only excerpts from din vde 0298 part 4 can be mapped at this point. The excel spreadsheet to the sectional calculation according to vde expects based on this input, the required thickness of the power lines with little effort and in accordance with the applicable din regulations vde 02984.
Iec 60228, class 5class 6 cables european cable stranding. Standards, formulae, tables protective measures eaton wiring manual 0611 105 1010 protection against indirect contact by means of disconnection or indication the conditions for disconnection are determined by the type of system in use and the protective device selected. Protection against electrical shock to iec 60364441din vde 0100410. The indicated values for bending radius stated in the following table are not permitted to fall below the value. Halogenfree singlecore high temperature cables, sheathed, for railway rolling stock.
The resulting temperature in the conductors is considered as well as the fuse. Tested in independent laboratories, vde certification is a mark of quality and assurance. Download this document for anlagenplanung at fachhochschule bielefeld for free and find more. In accordance with vde 0298 part 3 tensile strength. Cables sizes and current capacity electrical engineering. Pur drum reeling cable, halogen free, vdeulcsa approved application semoflex drum cable is specially designed for use on both spring operated and motorised cable reeling drums, it is also suitable for other applications such as. Betriebsbedingungen fur leitungen mit nennspannung bis. Din vde 02984 206 application of cables and cords in power installations part 4. Din vde 0298 part 1 to part 300, application of cables and flexible cords in power installations. Consult the manufacturer if speed exceeds 180 mmin festoon systems up to 240 mmin chemical resistance to oil according to vde iec standard weather resistance unrestricted use outdoor and indoor, uv resistant, moisture resistant.
General provisions and recommended values refer to the vde 0298 part 2 and part 4. Ever since the first electrotechnical standard vde 0100 was passed on november 23, 1895 at the wartburg castle in eisenach, germany, vde standards have been an inseparable part of the development of key technologies in electrical engineering, information technology and consumer protection. In other respects, din vde 0298300 hd 516 applies electrical parameters rated voltage uou 0. Permissible minimum bending radius for power cables acc. Shows the maximum resistance in that is permissible for untinned copper conductors in the stranding classes indicated. Din vde 02984 application of cables and cords in power installations part 4. See also din vde 0100, part 430 and din en 6020432. Conductor refer also to din vde 0295 insulation refer. Schutz gegen elektrischen schlag nach iec 60364441 din vde 0100410. Recommended currentcarrying capacity for sheathed and nonsheathed cables for fixed wirings in and around buildings and for flexible cables and cords. Strand makeup according to din vde 0295, iec 60228 and. Shows the maximum strand diameter, may be fewer strands as long as the maximum ohmskm is not exceeded ohms.
Din vde 0266 part 3 and part 4 halogen free cables with improved characteristics in the case of. Structure of stranded wires in accordance with vde 0295 and amplified lowest allowed bending radius in accordance with din vde 0298 part 3. The information portrayed in this table differs from that in. Standard halogenfree cables offer a large degree of safety to humans, nature. Din vde 0298 part 1 to part 300 application of cables and. It is necessary to take the reduction factors specified in din vde 02984 into consideration for other types of. Asinterface flat cable vazfksbk allied electronics. The cables can be installed free moveable, free hanging or fixed. Lowest allowed bending radius in accordance with din vde. Din vde 0298 part 1 to part 300 application of cables and flexible cords in power installations din vde 0472 part 1 to part 818 testing of cables, wires and flexible cords din vde 0473 up to part 811 insulating and sheathing mate rials of electric cables, common test methods. Reference to din vde standards power installations. Din vde 02983 application of cables and cords in power installations part 3. The intention for publishing this document in germany was to enable manufacturers to classify material as halogen free and to informto check with the public the necessity of such requirements.